Titre | Study on the largest hydraulic-fracturing-induced earthquake in Canada: observations and static stress-drop estimation |
| |
Auteur | Wang, B; Harrington, R M; Liu, Y; Kao, H ; Yu, H |
Source | Bulletin of the Seismological Society of America 2020 p. 1-12, https://doi.org/10.1785/0120190261 |
Image |  |
Année | 2020 |
Séries alt. | Ressources naturelles Canada, Contribution externe 20200033 |
Éditeur | Seismological Society of America |
Document | publication en série |
Lang. | anglais |
DOI | https://doi.org/10.1785/0120190261 |
Media | papier; en ligne; numérique |
Formats | pdf |
Province | Colombie-Britannique |
SNRC | 94A; 94H; 93O/09; 93O/10; 93O/11; 93O/14; 93O/15; 93O/16; 93P/09; 93P/10; 93P/11; 93P/12; 93P/13; 93P/14; 93P/15; 93P/16; 94B/01; 94B/02; 94B/03; 94B/06; 94B/07; 94B/08; 94B/09; 94B/10; 94B/11; 94B/14;
94B/15; 94B/16; 94G/01; 94G/02; 94G/03; 94G/06; 94G/07; 94G/08; 94G/09; 94G/10; 94G/11; 94G/14; 94G/15; 94G/16 |
Région | Fort St. John |
Lat/Long OENS | -123.5000 -120.0000 58.0000 55.5000 |
Sujets | secousses séismiques; formation de fissures; zones de failles; failles; milieux tectoniques; risque sismique; zones sismiques; séismologie; fracturation hydraulique; détermination des contraintes; Gestion
des risques; Sciences et technologie; tectonique |
Illustrations | cartes de localisation; histogrammes; spectres; graphiques |
Programme | Géosciences environnementales Gaz de schiste - sismicité induite |
Diffusé | 2020 07 21 |
Résumé | (disponible en anglais seulement) On 17 August 2015, an Mw 4.6 earthquake occurred northwest of Fort St. John, British Columbia, possibly induced by hydraulic fracturing (HF). We use data from 8
broadband seismometers located ~50 km from the hypocenter to detect and estimate source parameters of more than 300 events proximal to the mainshock. Stress drop values estimated using seismic moment and corner frequency from single event spectra and
spectral ratios range from ~1 to 35 MPa, within the typical range of tectonic earthquakes. We observe a ~5-day delay between the onset of fluid injection and the mainshock, a b-value of 0.78 for the sequence, and a maximum earthquake magnitude larger
than the prediction based on the total injection volume, suggesting the Mw 4.6 sequence occurred on a pre-existing fault and that the maximum magnitude is likely controlled by tectonic conditions. Results presented here show that pre-existing fault
structures should be taken into consideration, in order to better estimate seismic hazard associated with HF operations and develop schemes for risk mitigation in close proximity of HF wells. |
Sommaire | (Résumé en langage clair et simple, non publié) Le 17 août 2015, un tremblement de terre de magnitude 4,6 s'est produit au nord-ouest de Fort St. John, en Colombie-Britannique, au Canada. Cet
événement est considéré comme le plus grand tremblement de terre induit par fracturation hydraulique au Canada. Nous étudions les caractéristiques sismiques de ce tremblement de terre et constatons que la quantité de contrainte libérée par sa rupture
se situe dans la plage typique des tremblements de terre tectoniques. Nous remarquons également que la taille de cet événement est disproportionnellement plus grande que celle théoriquement prédite à partir de la quantité de liquide injecté, ce qui
suggère qu'il s'est probablement produit sur une faille préexistante. Nous concluons qu'une évaluation appropriée des failles préexistantes est importante dans l'atténuation du risque sismique des tremblements de terre induits. |
GEOSCAN ID | 325464 |
|
|