GEOSCAN, résultats de la recherche

Menu GEOSCAN


TitreAirborne time-domain electromagnetics for three-dimensional mapping and characterization of the Spiritwood Valley Aquifer
AuteurOldenborger, G A; Pugin, A J M; Pullan, S E
SourceSymposium on the Application of Geophysics to Environmental and Engineering Problems, abstracts volume; par Environmental & Engineering Geophysical Society; 2012.
Année2012
Séries alt.Secteur des sciences de la Terre, Contribution externe 20110309
RéunionSymposium on the Application of Geophysics to Environmental and Engineering Problems; Tucson, AZ; US; mars 25-29, 2012
Documentlivre
Lang.anglais
Mediapapier
ProvinceManitoba
SNRC62G/03; 62G/04; 62G/05; 62G/06
Lat/Long OENS-99.7667 -99.1333 49.4258 49.0000
Sujetslevés géophysiques; levés électromagnétiques; levés aéroélectromagnétiques; levés de conductivité; levés électriques; levés de reflexion sismiques; interpretations sismiques; interprétations géophysiques; aquifères; profils sismiques; géophysique; hydrogéologie
Illustrationslocation maps
ProgrammeAquifer Assessment & support to mapping, Géoscience des eaux souterraines
Résumé(disponible en anglais seulement)
The Geological Survey of Canada commissioned a helicopter-borne time-domain electromagnetic (HTEM) survey over a 1062 km2 area of the Spiritwood Valley in southern Manitoba in order to test the effectiveness of airborne time-domain electromagnetics for mapping and characterizing buried valley aquifers in the Canadian Prairies. The HTEM data exhibit rich information content; apparent conductivity maps clearly image the Spiritwood Valley in addition to a continuous incised valley along the broader valley bottom. We detect complex valley morphology with nested scales of valleys including at least three distinct valley features and multiple possible tributaries. Conductivity-depth images (CDI) derived from the TEM decays indicate that the fill materials within the incised valleys are more resistive than the broader valley fill, consistent with an interpretation of sand and gravel. Comparison of ground-based electrical resistivity and seismic reflection data allow for calibration of CDI models. Lateral spatial information is in excellent agreement between data sets. The seismic data reveal the presence of additional valley features that are not imaged by the HTEM data as having a distinct electrical signature, possibly due to diamicton fill. The CDI model underestimates the dynamic range of electrical conductivity while overestimating depths to valley bottoms; these issues are associated with finite system bandwidth, algorithm limitations and penetration depth. The integrated data sets illustrate that HTEM surveys have the potential to map complicated buried valley aquifers at a level of detail required for groundwater prospecting and management.
GEOSCAN ID289679